pedicure northampton, ma
twitter facebook rss

honeywell barcode scanner 1900 manualrobotic rideable goat

This template reads both OCR-A and OCR-B fonts.

%%EOF Any specific ASCII value, wildcard, or group can be repeated. However, there is no guarantee that interference will not occur in a particular installation. The scanner will read OCR-A, OCR-B, MICR E-13B, and SEMI Font, in a 6 to 60 point OCR typeface. Use only shielded data cables with this system. Multiple Pre-Defined OCR Templates You can enable combinations of Pre-Defined OCR Templates by scanning one the following bar codes. its position. However, you can also enter them by scanning the Enter OCR Template bar code, followed by the OCR Programming Codes, followed by a Menu Save code. Operation is subject to the following two conditions: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. Enter the password to open this PDF file: Honeywell TC500A Commercial Thermostat User Gude, Honeywell RTH111 Digital Non Programmable Thermostat User Manual, Honeywell Thermostat th6220d1002 Installation Manual, Honeywell TH8320R1003 Installation Manual, Honeywell Smart Programmable Thermostat RTH6500WF Smart Series Manual, Honeywell T4 pro Series Thermostat Manual, Honeywell Thermostatic Radiator Valves and Actuators, Honeywell T8624D IV Deluxe Chronotherm Thermostat Manual, Honeywell RLV4305 Programmable Thermostat RLV4305A1000 Manual, Honeywell T6 Pro Hydronic Programmable Thermostat User Guide, Honeywell T6 Pro Hydronic Programmable Thermostat Manual, Honeywell TH8321WF1001 Installation Guide, Honeywell Pro 4000 Series/TH4110D1007 Owner's Manual, Honeywell Lyric Round Wi-Fi Thermostat Manual, Honeywell RTH111B1024 Quick Installation Guide, Honeywell RTH2300B1038 Quick Installation Guide, Honeywell RTH230B Programmable Electronic Thermostat Installation Manual and User Guide. Note: Once OCR reading is enabled, you must select a Pre-Defined Template, page -3, or create a Custom OCR Template, page -8, in order to read OCR characters. 2D barcode scanner Xenon 1900 HD USB Schwarz Imager Black Hand-held USB. To discard your template, scan Discard OCR Template. Disclaimer Honeywell International Inc. (HII) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. Scan the OCR Off bar code to disable OCR reading. To reduce the overall size of templates, you may define common groups of ASCII characters and then use the defined group control character rather than repeating the same sequence over and over. Increase the separation between the equipment and receiver. Save the shipping container for later storage or shipping. The following examples can be read when the MICR E-13B Template is enabled: 123456789 01235 123456789 193412454 98765 568123977 67891788 70 Note that in the third example, there will be 2 separate output results because of the 4 space gap between the first and second fields. Enable Price Field Template You can enable multiple Pre-Defined OCR templates along with the Price Field template. Make sure the items in the carton match your order. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. The other weight schemes multiply the character value by a repetitive weight value that helps in identifying characters that have had their column locations switched. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. Honeywell supplies a free software tool for entering programming commands serially. Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc. The byte immediately following the Checksum control code (D) defines the type of checksum that will be used: Checksum Table Bit Position(s) Meaning 7,6: Weight Scheme 00: Weight Scheme: 1 01: Weight Scheme: 12 10: Weight Scheme: 13 11: Weight Scheme: 137 5: Checksum Type 0: Row 1: Block 4-0: Modulo Value Checksum Modulo - 5 Row Checksums (0) perform a checksum calculation on all characters preceding them up to the first character on the same row. OCR Programming Codes We recommend that you enter OCR Templates using serial commands. The X at the end of the line is a mod 36 block checksum with 137 weighting. This equipment generates, uses, and can radi- ate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. FzbmF*;^0.XjEg@1 honeywell 1952 xenon manual quick start manualslib manuals The templates define the OCR font as well as the layout of the text in a row and column format. The checksum character always starts with a weight of 1. $ Following the currency character, a numeric grouping of 3, 4, 5, or 6 digits is followed by a terminating letter 'E.' TupBO!CZPSC:TK]=wWY2D\5SFw}p8pi]6N%|C {X${eg@{he^82X|v'1(|-Ie`|tc%+>#9^ =>i?$Vw)Q3d} . FCm8$(%FhI+McTb_?LG+uc]Ytylu- N# The following examples can also be read when the Price Field Template is enabled: C6712 $801E C0217 4399E C0823 31559E C0331 706213E Scan the following bar code to enable the Price Field Template. configuration honeywell setting tab easyset honeywellaidc commands scanners export The breakdown: Control Code Description 1 New Template Code 2 OCR-B font 5 Wildcard: Numeric F Variable Character Repeat - 5 min, 7 max 05 07 0 End of Template Groups In a given character position, you must specify which values a text character may take. The template reads both OCR-A and OCR-B fonts. (=]'PnKCm2NyI"Oj F@vr|V11P7Nl_4ZG%X[JQWK7O=#[w6H3;iP4xE`>vRh:n;SolS:V=.^)En{V1 \j. * Upright Vertical, Bottom to Top Upside Down Vertical, Top to Bottom Pre-Defined OCR Templates Passport Template The Passport Template may be used to read passports, visas and official travel documents based on the ICAO standard. The breakdown: Control Code Description 1 New Template Code 3 Both OCR-A and OCR-B font 5 Wildcard: Numeric E Fixed Character Repeat - 8 times 0 8 0 End of Template Variable Character Repeat The Variable Character Repeat control code may be used to repeat a count for a character a variable number of times. 65 41 A 97 61 a 22 66 42 B 98 62 b 23 # 67 43 C 99 63 c 36 24 $ 68 44 D 100 64 d 37 25 % 69 45 E 101 65 e ACK 38 26 & 70 46 F 102 66 f 07 BEL 39 27 71 47 G 103 67 g 08 BS 40 28 ( 72 48 H 104 68 h 9 09 HT 41 29 ) 73, Dec Hex Char Dec Hex Char Dec Hex 160 A0 161 A1 Char Dec Hex Char 192 C0 224 E0 193 C1 225 E1 128 80 129 81 130 82 162 A2 194 C2 226 E2 131 83 163 A3 195 C3 227 E3 132 84 164 A4 196 C4 228 E4 133 85 165 A5 197 C5 229 E5 134 86 166 A6 198 C6 230 E6 135 87 167 A7 199 C7 231 E7 136 88 168 A8 200 C8 232 E8 137 89 169 A9 . Example: You need to read 8 numeric digits in either OCR-A or OCR-B: 12345678 The string would be: 1 3 5 5 5 5 5 5 5 5 0 The breakdown: Control Code Description 1 New Template Code 3 Both OCR-A and OCR-B font 5 Wildcard: Numeric - 8 times 5 5 5 5 5 5 5 0 End of Template A template may contain multiple distinct templates all within the same string. endstream endobj 261 0 obj <>>>/Filter/Standard/Length 128/O(J;pNmwy32\(4md)/P -1340/R 4/StmF/StdCF/StrF/StdCF/U(\r/ZCRm )/V 4>> endobj 262 0 obj <> endobj 263 0 obj <> endobj 264 0 obj <>stream Report damage immediately to the carrier who delivered the carton. We recommend that you select and/or enter OCR Templates using serial commands. Cordless area-imaging scanner and charge bases (18 pages), Battery-free wireless area imaging scanner and charge base (17 pages), Cordless area-imaging scanner for healthcare (16 pages), Manual will be automatically added to "My Manuals", Programming the Interface - Plug and Play, Verifone Ruby Terminal Default Settings, Wincor Nixdorf Beetle Terminal Default Settings, RS232 Word Length: Data Bits, Stop Bits, and Parity, Communication between the Cordless System and the Host, Out of Range and Back into Range with Batch Mode on, Resetting the Custom Defaults: All Application Work Groups, Changing the Scanner's Bluetooth PIN Code, Minimizing Bluetooth/Ism Band Network Activity, To Add a Carriage Return Suffix to All Symbologies, Intercharacter, Interfunction, and Intermessage Delays, Straight 2 of 5 Industrial (Three-Bar Start/Stop), Straight 2 of 5 IATA (Two-Bar Start/Stop), To Add a Test Code I.D. scanner symbol ls2208 zebra barcodes scanners manual user found instructions usb printers drawers receipt overview cash while Go to www.honeywellaidc.com and download the EZConfigScanning software tool. Connect the appropriate interface cable to the device first, then to the computer. hbbd``b`$o@D6$@i:"b0 !Hl cd2;:Fgd{` Reorient or relocate the receiving antenna. An asterisk (*) next to an option indicates the default setting. The breakdown (dark box indicates group definition): Control Code Description 1 New Template Code 2 Both OCR-A and OCR-B font 3 Defined Group 001 Group ID x41 ASCII hex value for A x42 ASCII hex value for B x43 ASCII hex value for C 5 Numeric Digit 4 Define Group End 5 3 Numeric Digits 5 5 A001 Defined Group, ID 001 0 End of Template See the ASCII Conversion Chart on page 21 for character to hex conversions. Product specifications, dimensions, warranty, and customer support information are also included. Passports and Format-A visas each consist of two rows of 44 OCR-B characters. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.

Online Technical Assistance You can also access technical assistance online at www.honeywellaidc.com. Any specific ASCII value, wildcard, or group can be repeated. This device must accept any interference received, including interference that may cause undesired operation. This device complies with part 15 of the FCC Rules. 260 0 obj <> endobj This Users Guide provides installation and programming instructions for the Xenon 1900 and 1902 area-imaging scanners. 5 G F E (1x5) + (3x16) + (1x15) + (3x14) = 110 Again, a value is obtained that is a multiple of 10, validating this row checksum. endstream endobj startxref Each row can have up to 50 characters, with up to 18 rows in a template, with a maximum of 320 characters.

Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte.

Sitemap 14

facebook comments:

honeywell barcode scanner 1900 manual

Submitted in: madewell petite pants |